美國SONOTECH公司SONO950高溫耦合劑
美國SONOTECH公司SONO950高溫耦合劑
產品價格:¥詢價(人民幣)
  • 規格:SONO950
  • 發貨地:深圳
  • 品牌:
  • 最小起訂量:1支
  • 誠信商家
    會員級別:標準會員
    認證類型:企業認證
    企業證件:通過認證

    商鋪名稱:深圳市泰立儀器儀表有限公司

    聯系人:牟小姐(小姐)

    聯系手機:

    固定電話:

    企業郵箱:taili668@vip.163.com

    聯系地址:深圳市龍崗區龍翔大道9009號珠江廣場A2棟13D

    郵編:518000

    聯系我時,請說是在線纜網上看到的,謝謝!

    商品詳情

      SONO 950 high temperature ultrasonic couplant

      Sono 950 provides non-toxic coupling for thickness gaging and flaw inspection from 600 (315) to 950 (510). Sono 950 will maintain acoustic coupling beyond 15 seconds to give ample time for obtaining good thickness readings


      Temperature Operating Range

      Thickness Gaging: 600°to950°F(315°to510) Flaw Inspection: 600°to725(315°to385)


      Benefits

      ·Provides an extended open time window for longer inspections.

      ·Non-toxic, non-irritating formula provides inspector safety

      Safety

      ·Non-toxic, non-irritating, biodegradable

      ·Smokes less at elevated temperatures than most high temperature coupling materials

      ·Contains NO perfluorocarbons or fluorinated material, which can cause adverse health effects at high temperatures

      ·Provides operator safety and convenience

      Chemistry

      Total Halogens....................................... <2,500ppm

      Sulfur..................................................<50,000ppm

      Properties

      Viscosity1

      Thin Paste...............................>3,000,000 cps

      (Brookfield LV #5@0.3rpm)

      1 At ambient temperature.

      Auto Ignition temperature………1040oF(560)

      Packaging

      2-oz (50 g) tube

      4-oz (100 g) tube quart (liter) gallon (4-liter)


      Extreme Temperature Guidelines

      ·For best results, allow a few seconds of “melt-time” before taking the temperature reading. Signal attenuation may occur if used at lower than recommended temperature.

      ·A couplant's upper temperature range for short duration thickness gaging is higher than when used for flaw detection.

      ·When testing on vertical or overhead surfaces, a thicker grade of couplant is likely to stay in place, but a thinner grade generally performs better on flat surfaces.

      ·No Sonotech couplant contains perfluorocarbons; thus "polymer plume fever" is not an operator hazard.

      Flash Po int and Auto Ignition

      Sonotech provides the flash point and auto-ignition temperature for each high temperature product.

      ·The Flash Point of a product is the lowest temperature at which vapors arising from the product will ignite momentarily when exposed to a flame.

      ·Auto Ignition is the temperature at which a substance ignites without other sources of energy.

      The system for flash point determination for high temperature products (>680oF/360oC) utilizes the Cleveland Open Cup test in which vapors are allowed to escape and therefore results in a higher temperature than a closed cup test.


      ·For the flash point of Sono 950 please reference the MSDS on opposing side.

    在線詢盤/留言
  • 0571-87774297  
    成人另类视频