商鋪名稱:廈門紀揚科技有限公司
聯系人:葉經理(小姐)
聯系手機:
固定電話:
企業郵箱:1094469569@qq.com
聯系地址:廈門市翔安區鼓巖路1號華論國際1003
郵編:361001
聯系我時,請說是在線纜網上看到的,謝謝!
主營:世界知名品牌的PLC 、DCS 系統備件 模塊
①Allen-Bradley(美國AB)系列產品》
②Schneider(施耐德電氣)系列產品》
③General electric(通用電氣)系列產品》
④Westinghouse(美國西屋)系列產品》
⑤SIEMENS(西門子系列產品)》
⑥銷售ABB Robots. FANUC Robots、YASKAWA Robots、KUKA Robots、Mitsubishi Robots、OTC Robots、Panasonic Robots、MOTOMAN Robots。
⑦estinghouse(西屋): OVATION系統、WDPF系統、MAX1000系統備件。
⑧Invensys Foxboro(福克斯波羅):I/A Series系統,FBM(現場輸入/輸出模塊)順序控制、梯形 邏輯控制、事故追憶處理、數模轉換、輸入/輸出信號處理、數據通信及處理等。Invensys Triconex: 冗余容錯控制系統、基于三重模件冗余(TMR)結構的zui現代化的容錯控制器。
⑨Siemens(西門子):Siemens MOORE, Siemens Simatic C1,Siemens數控系統等。
⑩Bosch Rexroth(博世力士樂):Indramat,I/O模塊,PLC控制器,驅動模塊等。
◆Motorola(摩托羅拉):MVME 162、MVME 167、MVME1772、MVME177等系列。
Emerson Rosemount 0065N34J0150N0530IMXAX8QGBR6
the YZ300 (YZ320) using a compatible PC with the Windows based YZ300P Programming software, available from Fireye and the appropriate hardware. Note: The YZ300 (YZ320) Interlock
Annunciator does not need to be connected to a BurnerLogix system to be custom programmed.
Note: Proper operation of the YZ300 (YZ320) requires a BurnerLogix YB110 (YB230) with an Engineering code of 3 or later or any
ZB110 (ZB230) chassis/amplifier (Engineering codes are found after the date code, e.g. 0636-03).
The Interlock Annunciator Module does not interfere with the normal operation of the BurnerLogix System. It expands the message
and diagnostic capability.
The wiring bases for the YZ300 (YZ320) measure 4 in. wide by 7 in. tall, consuming a minimum amount of cabinet space. The wiring
bases contain a 24 position terminal block, each position clearly numbered and each terminal utilizing a clamping mechanism to assure a
good mechanical connection.
The YZ300 (YZ320) Interlock Annunciator module provides operational information and reduces troubleshooting time and expense. It
expands the standard display messages of the BurnerLogix to identify the specific limit in the operating control circuit (L1-3) or running
interlock circuit (3-P) which caused the burner shutdown or lockout. For a detailed description of the BurnerLogix System, see Bulletins BL1001 or BLZ-1001.
PART NUMBER DESCRIPTION
YZ300 Interlock Annunciator Module used with the YB110 or ZB110 BurnerLogix chassis/amplifier,
120 VAC, +10%, -15%, 50/60 Hz
YZ320 Interlock Annunciator Module used with the YB230 or ZB230 BurnerLogix chassis/amplifier,
230 VAC, +10%, -15%, 50/60 Hz
60-2872-1 Wiring base, terminal blocks, closed with knockouts
60-2874-1 Wiring base, terminal blocks, open end
ED580-4, -8 YB110 or ZB110 to YZ300 interconnection cable in 4' and 8' lengths
YZ300P Windows based software for programming custom messages
EC485 RS232 to RS485 converter with power supply. Required to customize YZ300 messages
UC485 USB to RS485 converter with USB cable. Required to customize YZ300 messages
ED512-2, 4, -8 Cable with RJ12 connectors on each end. Required to customize YZ300 lockout alarm messages
FIREYE PRIMELINE PRODUCTS ? 19
INTOUCH WIRELESS MONITORING SYSTEM Bulletin INT-1000
The inTouch Wireless Monitoring System provides continuous monitoring up to 10 FlameMonitor and/or MicroM flame safeguard controls. The inTouch System also provides 4 drycontact and 4 AC power inputs. In the event of a lockout or contact closure, the inTouch system reports the condition causing the lockout and also the make, model and location of the
equipment over the wireless cellular network using a wide variety of delivery methods, i.e. telephone, fax, e-mail, pager (alphanumeric, numeric). The system can be configured to provide
customized messages for each monitored point and safety lockout message for the flame safeguard control. Every 24 hours, the inTouch will transmit to the server message center information about the connected flame safeguard controls, e.g. system hours, burner hours, burner
cycles and total number of lockouts.
DIMENSIONS
PART NUMBER INTOUCH MAIN COMPONENT
IT1000 Monitor up to 10 Flame-Monitors, MicroM or BurnerLogix Y & Z controls, 4 dry-contact, 4 AC input. Complete
with 3 Quad Band GSM antenna and communication cable.
PART NUMBER INTOUCH ACCESSORIES
N018032-10 Remote Quad Mount Antenna without mounting kit (includes 10 ft coax cable)
N018040-KIT Remote Quad Mount Antenna with mounting kit (includes 10 ft coax cable)
N200233-00 Remote mount U bolt - 1/2” OD pipe size (included in remote mounting kit)
N250339-00 Remote mounting bracket (included in remote mounting kit)
59-509-10,-15,-20,-25 Coax cable extension
ED512-2,-4,-8 Cable with RJ12 connector used to connect BurnerLogix and Flame-Monitor to ED-610
ED610 Telephone jack adapter board for multi-dropping controls
2.25
1.13
8-5/16
9.87
3-3/8
#0.40
3 PLACES
3-3/4
2 2
1-1/16
20 ? FIREYE PRIMELINE PRODUCTS
NEXUS NX6100 INTEGRATED BURNER CONTROLER Bulletin NEX-6100
The Fireye NEXUS NX6100 Integrated Controller is a microprocessor based, Flame
Safeguard and Parallel Positioning Combustion Controller built into one compact,
user configurable package. The system consists of the Controller, Display, Temperature / Pressure Sensors, Servo-Motors and optional Comfire Software.
The Flame Safeguard portion of the control package provides burner sequencing
including safe start check, proof of main valve closure, selectable main gas safety
proving sequence, supervised pre-purge, low fire starting position, pilot and main
trials for ignition, main flame supervision, and post purge. Safety event timings are
provided to meet North American and CE Standards. Time proven Fireye Flame
Scanners and amplification circuits using UV, UV-Self Check and Infrared sensors,
provide fast reliable scanning of most commonly burned fuels. For exotic fuels and
applications, the NX6100 is also compatible with Fireye Phoenix and InSight integrated Flame Scanners. Seven low voltage and two line voltage user defined auxiliary inputs provide supervision of safety critical and nonsafety critical inputs. A large menu of alarm messages provides enhanced diagnostics.
Control of up to four profiles using an independent Servo-Motor for each controlled element allows precise positioning, accurate to 0.1°, of
the fuel and air metering devices over the burner's firing range. Each profile can be defined to include up to 10 servomotors. Profiles can