商鋪名稱:廈門紀揚科技有限公司
聯系人:葉經理(小姐)
聯系手機:
固定電話:
企業郵箱:1094469569@qq.com
聯系地址:廈門市翔安區鼓巖路1號華論國際1003
郵編:361001
聯系我時,請說是在線纜網上看到的,謝謝!
主營:世界知名品牌的PLC 、DCS 系統備件 模塊
①Allen-Bradley(美國AB)系列產品》
②Schneider(施耐德電氣)系列產品》
③General electric(通用電氣)系列產品》
④Westinghouse(美國西屋)系列產品》
⑤SIEMENS(西門子系列產品)》
⑥銷售ABB Robots. FANUC Robots、YASKAWA Robots、KUKA Robots、Mitsubishi Robots、OTC Robots、Panasonic Robots、MOTOMAN Robots。
⑦estinghouse(西屋): OVATION系統、WDPF系統、MAX1000系統備件。
⑧Invensys Foxboro(?怂共_):I/A Series系統,FBM(現場輸入/輸出模塊)順序控制、梯形 邏輯控制、事故追憶處理、數模轉換、輸入/輸出信號處理、數據通信及處理等。Invensys Triconex: 冗余容錯控制系統、基于三重模件冗余(TMR)結構的zui現代化的容錯控制器。
⑨Siemens(西門子):Siemens MOORE, Siemens Simatic C1,Siemens數控系統等。
⑩Bosch Rexroth(博世力士樂):Indramat,I/O模塊,PLC控制器,驅動模塊等。
◆Motorola(摩托羅拉):MVME 162、MVME 167、MVME1772、MVME177等系列。
Emerson Rosemount 0065N34J0150N0395A2IMXAX8QGBR6
YB230UVSC 230 VAC input with UV self-check amplifier
YB230IR 230 VAC input with IR auto-check amplifier
YB230FR 230 VAC input with flame rectification amplifier
YB230DC 230 VAC input with direct coupled amplifier for use with 85UVF4-1QDWR or InSight scanner (with 59-
497-020WR cable)
PART NUMBER DESCRIPTION
YP100 Keypad selectable parameters, non-recycle operation, modulation, open damper proving, 4 second FFRT
YP102 Keypad selectable parameters, non-recycle operation, modulation, open damper proving, 2 second FFRT
YP138 Keypad selectable parameters, non-recycle operation, modulation, open damper proving, indefinite pilot
hold, revert to pilot from auto, 4 second FFRT
YP118 Keypad selectable parameters, non-recycle operation, modulation, open damper proving, indefinite pilot
hold, revert to pilot from auto, 1 second FFRT
YP200 Keypad selectable parameters, recycle operation, modulation, 4 second FFRT
YP202 Keypad selectable parameters, recycle operation, modulation, 2 second FFRT
YP300 Keypad selectable parameters, recycle operation, low fire start, early spark termination, 4 second FFRT
YP302 Keypad selectable parameters, recycle operation, low fire start, early spark termination, 2 second FFRT
YP113 Keypad selectable parameters, non-recycle operation, modulation, open damper proving, 1 second FFRT
PART NUMBER DESCRIPTION
BLV512 Display, 2 line X 16 characters, VFD, with cable, NEMA 4
BLL510 Display, 2 line X 16 characters, LCD, with cable, NEMA 4
PART NUMBER DESCRIPTION
60-2810-1 Pigtail wires, 4 foot long, 4"W x 5"H
60-2812-1 Closed base with terminal block and knockouts, 4"W x 7"H
60-2814-1 Open base with terminal block. 4"W x 7"H
PART NUMBER DESCRIPTION
129-178-4 Kit, remote mounting, BurnerLogix display, 4 ft. cable, provides NEMA 4 protection
129-178-8 Kit, remote mounting, BurnerLogix display, 8 ft. cable, provides NEMA 4 protection
BLD500 Blank display module, included with YB module
IT1000 Alarm annunciation system using wireless technology
PPC6000 Parallel Positioning System
61-5745-3 Shutter drive assembly for redundant self-check 45UV5-1005 scanners
57YB4-5000 Tester for use with BurnerLogix YB control, 120 VAC
PART NUMBER DESCRIPTION
16 ? FIREYE PRIMELINE PRODUCTS
ZB110/ZB230 FIREYE BURNERLOGIX? Z CONTROL Bulletin BLZ-1001
The Fireye® BurnerLogix? Z System expands on the standard BurnerLogix Y System by combining boiler control functions with the same burner management control found in the Y system.
The result is a single compact package that can directly control the boiler's output firing rate
based on either input pressure or temperature or both.
The BurnerLogix Z System is designed to provide the proper burner sequencing, ignition and
flame monitoring protection on automatically ignited oil, gas, and combination fuel burners.
Through the display, the operator programs the desired setpoint, cut in, cut out and modulating
range and with PID control, the BurnerLogix Z System controls the burner/boiler from start up
through shutdown, precisely maintaining the desired setpoint.
The BurnerLogix Z System continuously monitors interlocks and limits found in the L1-3 and 3-
P circuits as it programs the burner/blower motor, ignition and fuel valves to provide for proper
and safe burner operation. VFD and LCD displays are available that may be either plugged in or
mounted remotely to give full language descriptors of current status and diagnostic lockout information as well as provide a user friendly menu system to make setting the boiler parameters easy
and understandable.
Through SMART LED'S, located on the front cover or through the display interface, the control provides current operating status and lockout information in the event of a safety shutdown. Following are some of the major control and monitor capabilities provided by the BurnerLogix Z System:
? Operating Control Function for automatic sequencing of the boiler system to start and stop the boiler to meet system demand.
? Full Modulation Control of fuel and combustion air through the firing rate motor to meet system demand.
? Solid State Sensors to monitor steam pressure, water temperature, stack temperature, boiler water temperature,
or outdoor air temperature.
? High Pressure and Temperature Alarm Limits based on inputs from solid state sensors. Exceeded limits will open
interlock circuit to the flame safeguard control for shutdown of the burner and boiler.
? Cold Start Thermal Shock Protection to slowly increase the burner firing rate on a cold start to limit mechanical
stress due to thermal differences.
? Multiple Lead/Lag operation of two or more boilers.
? Remote Communication Capability allows reading and writing of all setpoint information.
? Assured low fire cut off prevents unnecessary stress caused by burner shut down at high fire.
? Auto / Manual firing rate control with bumpless transfer
A complete BurnerLogix Z System includes the ZB110 (ZB230) chassis equipped with the type of flame amplifier required for the application, appropriate flame detector, plug-in programmer module, appropriate temperature/pressure transducer, wiring base and alpha-numeric
display. Interchangeable YP1XX type programmer modules allow for complete versatility in selection of function, timing and flame failure
response times.
The ZB110 (ZB230) is a chassis/flame amplifier module complete with mounting screws and blank display module. The display module
(BLV512 or BLL510), if required, must be ordered separately. Functions such as pre-purge time, recycling or non-recycling interlocks, high
fire proving interlock, and trial for ignition timing of the pilot and main flame are determined by the programmer module. The BurnerLogix Z