商鋪名稱:廈門紀揚科技有限公司
聯系人:葉經理(小姐)
聯系手機:
固定電話:
企業郵箱:1094469569@qq.com
聯系地址:廈門市翔安區鼓巖路1號華論國際1003
郵編:361001
聯系我時,請說是在線纜網上看到的,謝謝!
主營:世界知名品牌的PLC 、DCS 系統備件 模塊
①Allen-Bradley(美國AB)系列產品》
②Schneider(施耐德電氣)系列產品》
③General electric(通用電氣)系列產品》
④Westinghouse(美國西屋)系列產品》
⑤SIEMENS(西門子系列產品)》
⑥銷售ABB Robots. FANUC Robots、YASKAWA Robots、KUKA Robots、Mitsubishi Robots、OTC Robots、Panasonic Robots、MOTOMAN Robots。
⑦estinghouse(西屋): OVATION系統、WDPF系統、MAX1000系統備件。
⑧Invensys Foxboro(?怂共_):I/A Series系統,FBM(現場輸入/輸出模塊)順序控制、梯形 邏輯控制、事故追憶處理、數模轉換、輸入/輸出信號處理、數據通信及處理等。Invensys Triconex: 冗余容錯控制系統、基于三重模件冗余(TMR)結構的zui現代化的容錯控制器。
⑨Siemens(西門子):Siemens MOORE, Siemens Simatic C1,Siemens數控系統等。
⑩Bosch Rexroth(博世力士樂):Indramat,I/O模塊,PLC控制器,驅動模塊等。
◆Motorola(摩托羅拉):MVME 162、MVME 167、MVME1772、MVME177等系列。
Emerson Rosemount 0065C32J0080N0225A2IMG1TBX8QGBR6
EP100F Selectable Purge, Selectable TFI, 4 Sec FFRT, Non-Recycle, Modulation, French language.
EP100S Selectable Purge, Selectable TFI, 4 Sec FFRT, Non-Recycle, Modulation, Spanish language.
EP260 30 Sec. Purge, 10 & 15 Sec. TFI, 4 Sec FFRT, Recycle, Modulation
EP265 30 Sec. Purge, 10 & 15 Sec. TFI, 2 Sec FFRT, Pilot Stabilization, Recycle, Modulation.
EP270 30 Sec. Purge, 5 & 10 Sec. TFI, 4 Sec FFRT, Early Spark Termination, Recycle, Modulation
EP200F Selectable Purge, Selectable TFI, 4 Sec FFRT, Recycle, Modulation, French language.
EP200S Selectable Purge, Selectable TFI, 4 Sec FFRT, Recycle, Modulation, Spanish language.
EP380 30 Sec. Purge, 5 & 10 Sec. TFI, 4 Sec FFRT, Recycle, No Modulation
EP381 15 Sec. Purge, 5 & 10 Sec. TFI, 4 Sec FFRT, Recycle, No Modulation
EP382 0 Sec. Purge, 5 & 10 Sec. TFI, 4 Sec FFRT, Recycle, No Modulation
EP383 Selectable Purge, 5 and 10 Sec. TFI, Selectable Recycle / Non-Recycle via ED510, No Modulation,
No Agency Approvals.
EP387 Selectable Purge (15 sec. min.), Selectable TFI, Selectable Recycle / Non-Recycle, No Modulation,
infinite hold on M-D circuit.
EP390 90 Sec. Purge, 5 & 10 Sec. TFI, 4 Sec FFRT, Recycle, No Modulation
EP300F 4 Sec FFRT, Selectable Purge, Selectable Recycle, Non-Recycle, No Modulation, French language.
EP300S 4 Sec FFRT, Selectable Purge, Selectable Recycle, Non-Recycle, No Modulation, Spanish language.
PROGRAMMERS FOR USE WITH INTEGRATED FLAME SCANNERS
EP178 Keypad adjustable purge time, PTFI, MTFI, post purge, early spark termination, pilot proving period, and indefinite hold on
low fire start. Non-Recycle, Modulation. For use with EDC1 and EDC2 amplifiers and 85UVF4-1QDWR, 85IRF4-
1QDWR,or InSight scanners (with 59-497-020WR cable).
EP378 Keypad adjustable purge time, PTFI, MTFI, post purge, early spark termination, pilot proving period, and indefinite hold on
low fire start. Selectable Recycle, Non-Recycle. No modulation. For use with EDC1 and EDC2 amplifiers and 85UVF4-
1QDWR, 85IRF4-1QDWR or InSight scanners (with 59-497-020WR cable).
FIREYE PRIMELINE PRODUCTS ? 11
EPD Programmer Modules Bulletins EPD-1601, EPD-2601, EPD-3801
The EPD programmers offer a cost effective version of the Flame-Monitor control. EPD style programmers provide the same start-up programming, safe start
check, and flame monitoring supervision as their counterpart EP style programmers. The major difference between EP and EPD style programmers is that the
EPD programmers incorporate a built-in display consisting of seven (7) LED
indicator lights to annunciate the current operating status of the Flame-Monitor
control, as well as the reason of the last lockout condition. EPD programmers
provide a switch-selectable option that requires the air flow switch (terminals 3-
P) to be open at the start of the operating cycle. The EPD programmers include
an RJ45 style connector to interface with a remote alpha-numeric display (P/N
ED510)1 and two (2) RJ12 connectors for Modbus communications wired in a
multi-drop configuration.
The EPD programmers do not require the ED510 alpha-numeric display to operate. The ED510 display is optional for EPD programmers, but is required for the
EP-style programmers.
The EPD Flame-Monitor System can be upgraded to include an E300 Expansion
Module (remote ED510 alpha-numeric display required). A set of test jacks
located on the front of the programmer module provide a 0-10 VDC output to
indicate flame signal strength.
1.The EPD programmers must have an Engineering code of 02 or higher to interface with an ED510 display.
PART NUMBER DESCRIPTION
EPD160 30 Sec. Purge, 10 & 15 Sec. TFI, Non-Recycle Modulation
EPD161 30 Sec. Purge, 10 & 30 Sec. TFI, Non-Recycle, Modulation
EPD167 30 Sec. Purge, 10 & 15 Sec. TFI, Non-Recycle, Modulation, Infinite Hold on M-D circuit.
EPD170 30 Sec. Purge, 5 & 10 Sec. TFI, Early Spark Termination, Non-Recycle, Modulation
EPD260 30 Sec. Purge, 10 & 15 Sec. TFI, Recycle, Modulation
EPD261 30 Sec. Purge, 10 & 30 Sec. TFI, Recycle, Modulation
EPD270 30 Sec. Purge, 5 & 10 Sec. TFI, Early Spark Termination, Recycle, Modulation
EPD380 30 Sec. Purge, 5 & 10 Sec. TFI, Recycle, No Modulation
EPD381 15 Sec. Purge, 5 & 10 Sec. TFI, Recycle, No Modulation
EPD382 0 Sec. Purge, 5 & 10 Sec. TFI, Recycle, No Modulation
EPD390 90 Sec. Purge, 5 & 10 Sec. TFI, Recycle, No Modulation
GENERAL COMMENTS
EPD100 and EPD200 series programmers provide an additional 30 second low-fire purge.
All programmers offer selectable Prove Air Flow (3-P circuit) Open To Start feature
All programmers have 4 second FFRT.
EPD Style Programmers include a built-in LED display.
CAUTION: While programmers are mechanically interchangeable in that they mate with a
common wiring base, you should select the correct model for your application. Inappropriate
application of a control could result in an unsafe condition hazardous to life and property.
Selection of a control for a particular application should be made by a competent professional,
such as a boiler/burner service technician licensed by a state or other government agency.
12 ? FIREYE PRIMELINE PRODUCTS
FLAME AMPLIFIER MODULES Bulletin EAMP-1