主營:世界知名品牌的PLC 、DCS 系統備件 模塊
①Allen-Bradley(美國AB)系列產品》
②Schneider(施耐德電氣)系列產品》
③General electric(通用電氣)系列產品》
④Westinghouse(美國西屋)系列產品》
⑤SIEMENS(西門子系列產品)》
⑥銷售ABB Robots. FANUC Robots、YASKAWA Robots、KUKA Robots、Mitsubishi Robots、OTC Robots、Panasonic Robots、MOTOMAN Robots。
⑦estinghouse(西屋): OVATION系統、WDPF系統、MAX1000系統備件。
⑧Invensys Foxboro(?怂共_):I/A Series系統,FBM(現場輸入/輸出模塊)順序控制、梯形 邏輯控制、事故追憶處理、數模轉換、輸入/輸出信號處理、數據通信及處理等。Invensys Triconex: 冗余容錯控制系統、基于三重模件冗余(TMR)結構的zui現代化的容錯控制器。
⑨Siemens(西門子):Siemens MOORE, Siemens Simatic C1,Siemens數控系統等。
⑩Bosch Rexroth(博世力士樂):Indramat,I/O模塊,PLC控制器,驅動模塊等。
◆Motorola(摩托羅拉):MVME 162、MVME 167、MVME1772、MVME177等系列。
Emerson Rosemount 0065N34J0150N0865IMXAX8QGBR6
? Continuous display of current burner operating status, including first out
annunciation in the event of a lockout condition.
? Three (3) key, tactile dome keypad provides historical information of the
burner, last six (6) lockout conditions (with burner cycle and burner hour
time stamp), assign messages associated with the operation of the E300
expansion module, and diagnostic messages.
? Design which mounts directly onto the front face of the EP style programmers.
? RJ style connector for connection to the EP and EPD style programmers.1
? Remote display capability with the EP and EPD style programmers using
standard DIN sized opening and remote mounting kit.
DIMENSIONS TO REMOTE MOUNT ED510 DISPLAY
1.The EP programmers must have an Eng. code of 28 or higher, the EPD programmers must have an Eng. code of 02 or higher.
Part Number Description
ED510 2 line x 16 character LCD display with keypad.
ED580-1 ED510 Display cable with RJ45 connector – 1 1/4 inch
ED580-2 ED510 Remote display cable with RJ45 connector – 2 feet
ED580-4 ED510 Remote display cable with RJ45 connector – 4 feet
ED580-8 ED510 Remote display cable with RJ45 connector – 8 feet
129-145-1 Remote display (ED510) mounting kit with 4 ft. cable.
129-145-2 Remote display (ED510) mounting kit with 8 ft. cable.
129-145-3 Remote display (ED510) mounting kit with 2 ft. cable.
ED610 Adaptor for mounting ED510 display further than 8 feet away from control.
KEYPAD/DISPLAY
FRONT
GASKET
PEM NUT
INSIDE
MOUNTING
SCREW
MOUNTING
PLATE
MAXIMUM THICKNESS CONNECTOR
CABLE (2’, 4’, or 8’)
TO EP/EPD PROGRAMMER
5/64 INCH (2.0mm) PANEL
3.63
(92.0)
3.63
(92.0)
SUGGESTED PANEL CUTOUT DIMENSIONS
10 ? FIREYE PRIMELINE PRODUCTS
EP PROGRAMMER MODULES Bulletins EP1601, EP2601, EP3801
The Fireye EP Programmer Modules are used with the E100 and E110 Flame-Monitor
controls. They provide start-up programming, safe-start-check, and flame monitoring
supervision. They prove high-fire purge interlock (EP100 series only), low-fire start position and fuel valve end-switch safety checks. A running interlock circuit monitors the limit
switches, air flow switches, and fuel pressure switches.
The EP programmers de-energize all fuel valve circuits with 4 seconds (max.) following a
flame failure(2 seconds for the EP165, EP166, EP265), or at the end of the pilot-trial-forignition period if no flame is detected. A modulator motor circuit is provided (EP100 and
EP200 series only). The programmers have a Check-Run switch to stop the control
sequence to aid in the set-up and check out of the burner and its associated interlocks.
The programmers store the burner cycles, hours, and lockout history.
The EP programmers offer the following selectable functions: purge timing, prove the
Running Interlock circuit is open at the start of the cycle, recycle or non-recycle operation
(EP300 series only), intermittent or interrupted operation of terminal 6 (EP300 series
only). The programmers include an RJ45 connector for the ED510 display module, and
two RJ12 connectors for Modbus Communications.
PART NUMBER DESCRIPTION
EP160 30 Sec. Purge, 10 & 15 Sec. TFI, 4 Sec FFRT, Non-Recycle, Modulation
EP161 30 Sec. Purge, 10 & 30 Sec. TFI, 4 Sec FFRT, Non-Recycle, Modulation
EP163 Selectable Purge (30 sec min.), selectable TFI via ED510 display, Non-Recycle.
EP165 30 Sec. Purge, 10 Sec. TFI, 2 Sec FFRT, Pilot Stabilization, Non-Recycle, Modulation.
EP166 Selectable Purge (30 sec min.), Pilot Stabilization, Non-Recycle, 10 and 15 sec TFI programmer.
EP170 30 Sec. Purge, 5 & 10 Sec. TFI, 4 Sec FFRT, Early Spark Termination, Non-Recycle, Modulation
EP174 Selectable Purge (30 sec min.), 5 and 10 sec. TFI, Non-Recycle, Early Spark Termination.
M-D circuit must be proven through the completion of MTFI.
EP177 Early Spark Termination. ED510 to Select Purge (30 sec min.), Prove Air Flow, Prove High Fire,
Prove Low Fire, and Post Purge. Early Spark Termination. Infinite Hold on M-D circuit.